# CAPLfunctionARILFaultInjectionDisturbSequenceCounter

# ARILFaultInjectionDisturbSequenceCounter

[Valid for](../../../Shared/FeatureAvailability.md): CANoe DE • CANoe4SW DE

## Function Syntax

```plaintext theme={null}
long ARILFaultInjectionDisturbSequenceCounter(dbMsg dbMessage, long type, long disturbanceMode, long disturbanceCount, long disturbanceValue, long continueMode);
long ARILFaultInjectionDisturbSequenceCounter(dbMsg dbMessage, char signalGroupName[], long type, long disturbanceMode, long disturbanceCount, long disturbanceValue, long continueMode);
```

## Description

Disturbs the SQC or TGL of a PDU or signal group (see [Supported Features](../../../CANoeCANalyzer/LibrariesPackages/AUTOSARpduIL/AUTOSARpduILFeatures.md)).

The function without the parameter for the signal group will only disturb SQCs or TGLs that are not part of a signal group.

## Parameters

* **dbMessage**: The symbolic name of a PDU in the database.
* **signalGroupName**: The symbolic full name of the signal group.
* **type**:
  * 0: SQC
  * 1: TGL
  * Others: all other values are reserved
* **disturbanceMode**: Defines the function for the disturbance:
  * **0**: Value - Sets the SQC fix to the value of parameter `disturbanceValue`.
  * **1**: Freeze - Current signal value is used (`disturbanceValue` is not used).
  * **2**: Random - Random value is used (`disturbanceValue` is not used).
  * **3**: Offset - Signal value is increased by value of parameter `disturbanceValue`.
* **disturbanceCount**:
  * **-1**: Infinite - Disturbance is continuously applied.
  * **0**: Stop - An active disturbance is stopped and the SQC will be calculated again appropriately.
  * **n > 0**: Count - Do exactly n disturbances.
* **disturbanceValue**: According to the disturbance mode the SQC will optionally be set to this value.
* **continueMode**: Defines the signal value when the disturbance is stopped:
  * **0**: Correct Counter - The counter will continue as if there had never been a disturbance: 0, 1, 2, 6, 6, 5, 6 …
  * **1**: Last Valid Counter - The counter will continue by increasing last valid counter: 0, 1, 2, 6, 6, 3, 4 ...
  * **2**: Last Value - The counter will continue by increasing the last transmitted value: 0, 1, 2, 6, 6, 7, 8 ...

## Return Values

* **0**: No error.
* **Others**: [Error](../../../CANoeCANalyzer/LibrariesPackages/AUTOSARpduIL/AUTOSARpduILReturnCodes.md) in module.

## Example

—