# CAPLfunctionDoIPEnableTLS

# DoIP\_EnableTLS

[Valid for](../../../Shared/FeatureAvailability.md): CANoe DE

**Note**\
The following DoIP CAPL function is only available with the modeling library **DoIP.dll** and eventually an appropriate implementation of the CAPL Callback Interface. Information about the DoIP DLL and the CAPL Callback Interface you find here:

* [DoIP CAPL Introduction](../CAPLDiagnosticDoIP.md)
* [AN-IND-1-012\_CAPL\_Callback\_Interface.pdf](javascript:startDemoLoader\('AN-IND-1-012_CAPL_Callback_Interface.pdf'\))
* [AN-IND-1-026\_DoIP\_in\_CANoe.pdf](javascript:startDemoLoader\('AN-IND-1-026_DoIP_in_CANoe.pdf'\))

TLS can be used only for simulation nodes (CAPL node, test module, etc.) that have security enabled for the TCP/IP stack, configured for the node with DoIP.dll in the CANoe Security Configuration.

## Function Syntax

```plaintext theme={null}
void DoIP_EnableTLS(dword mode, char name[]);
```

## Description

Enables secure communication for DoIP tester or ECU simulation. If enabled, DoIP communication is carried out via TLS (Transport Layer Security).

**Note**\
TLS must be enabled before DoIP communication starts. It is recommended to call the function **on preStart** or **on start** before configuring TP parameters.

## Parameters

* **mode**
  * 0: disable TLS, no secure communication.
  * 1: enable TLS by routing activation response code (RARC) 0x07.
  * 2: (tester only) enable TLS. Only secure connection is allowed. If ECU responds with RARC 0x10 on the first unsecure routing activation, the tester stops communication.
  * 3: (tester only) enable TLS. Tester connects to ECU directly via TLS without establishing connection on unsecure port (e.g. 13400).

* **name**
  * (ECU simulation) name of the server certificate, which must be used for TLS connection. It must be one of the certificates, available in the security profile, selected for the TCP/IP stack of the ECU simulation node.
  * (Tester) name of the client certificate. Currently, client certificates are not supported for DoIP. The parameter is reserved for future use. It must be an empty string "".

## Return Values

—

## Example

**Example 1**

```plaintext theme={null}
on preStart
{
  // enable TLS for ECU simulation
  // use certificate 'Server1' (security profile 'DoIP over TLS Demo')
  DoIP_EnableTLS(1, "Server1");
}
```

**Example 2**

```plaintext theme={null}
on preStart
{
  // enable TLS for tester
  DoIP_EnableTLS(2, "");
}
```