Class: scopeSerialBitAnalysisViolationData
Valid for: CANoe DE • CANoe:lite DE This structure contains the violation data for a bit.Methods
—Attributes
-
BitField
The bit field e.g. LIN Sync Byte Field, of the bit used for the duty cycle measurement.
Type:long
Access Limitations: Read-only -
BitNo
The bit number within the field (starts with 0).
Type:dword
Access Limitations: Read-only -
BitStartTime
The time the bit started in ns.
Type:int64
Access Limitations: Read-only -
BitLevel
0: Dominant
1: Recessive
Type:byte
Access Limitations: Read-only -
SamplePointVoltage
The voltage of the bit at the sample point.
Type:long
Access Limitations: Read-only -
DisturbanceTimeStart
Relative time in [ns] to BitStartTime where the violation of the bitmask starts.
Type:long
Access Limitations: Read-only -
DisturbanceStartVoltage
Voltage level in [mV] on the DisturbanceTimeStart.
Type:long
Access Limitations: Read-only -
DisturbanceTimeEnd
Relative time in [ns] to BitStartTime where the violation of the bitmask end.
Type:long
Access Limitations: Read-only -
DisturbanceEndVoltage
Voltage level in [mV] on the DisturbanceTimeEnd.
Type:long
Access Limitations: Read-only -
ScopeSamplePeriod
The sample period of the scope in [ns].
Type:float
Access Limitations: Read-only -
ScopeVoltageTolerance
The voltage tolerance of the scope measurement probe [mV].
Type:float
Access Limitations: Read-only