Skip to main content
Open topic with navigation CAPL Functions » K-Line » KLine_GetMeasuredInitParameter

KLine_GetMeasuredInitParameter

Valid for: CANoe DE

Function Syntax

Description

Retrieves the different parameters of the init patterns.

Parameters

  • parameterID
    Value range: 0-10
    0: KeyByte1
    1: Keybyte2
    2: TiniL
    3: Twup
    4: W4 between key byte 2 and inverted key byte 2
    5: W1
    6: W2
    7: W3
    8: W4
    9: W4 between inverted keybyte 2 and inverted address byte
    10: BaudRate from sync pattern

Return Values

Parameter value or error code.