Skip to main contentOpen topic with navigation
CAPL Functions » MOST » Error Codes of CAPL Functions
MOST: Error Codes of CAPL Functions
Valid for: CANoe DE
- kMostOK = 0: No Error occurred.
- kMostInvalidChannel = -1: The operation was requested for an invalid channel number.
- kMostNoConnection = -2: The driver was unable to establish a connection to the MOST interface hardware. Check the connection settings in the Hardware Configuration dialog under the menu path Configuration|Hardware Configuration.
- kMostIllegalTime = -3: The function was called in the wrong phase of the measurement. For example, the OptoLyzer mode can only be changed in the ‘preStart’ function.
- kMostWrongThread = -4: For technical reasons, this function may not be called from this area of CANoe DE. Not all functions can be called from CAPL nodes in the analyzing setup.
- kMostWrongHWMode = -5: The network interface to the MOST bus is in a state in which the called function is unavailable.
- kMostTxQueueFull = -6: The transmit queue of 256 Messages is full, while trying to send another message.
- kMostHWBusy = -7: Unable to perform the desired action due to hardware overload.
- kMostWrongHWType = -8: This functionality is not supported by the hardware used.
- kMostParameterOutOfRange = -9: One or more function parameters lie outside of their valid value ranges.
- kMostDriverCallFailed = -10: The MOST hardware driver returned an error. Please make sure that the driver has been properly installed and that the hardware is operationally ready.
- kMostAsInvalidChannel = -21: The function was called for an invalid channel.
- kMostAsDoubleOp = -22: The function cannot be executed, because its results already apply. (e.g., a CAPL node has already been registered in the Local FBlockList)
- kMostAsIllegalTime = -23: The function cannot be executed in this phase of the simulation cycle.
- kMostAsParamNotAvailable = -24: The requested parameter value is unavailable.
- kMostAsNotAvailable = -25: The function is unavailable or the MOST Application Socket is inactive.
- kMostAsBeforeNetOn = -26: This function cannot be called before NetOn.
- kMostAsInvalidParameter = -29: At least one parameter passed with the function lies outside of its valid value range.
- kMostXML4CAPLGeneralExecError = -30: General execution error.
- kMostXML4CAPLUnknownMsg = -31: The specified message cannot be dissolved with the available function catalogs.
- kMostXML4CAPLMsgSizeExceeded = -32: The function cannot be executed, since the size of the specified message is exceeded.
- kMostXML4CAPLUnknownParamAdr = -33: The specified parameter address cannot be dissolved with the available function catalogs.
- kMostXML4CAPLParamNotFoundInMsg = -34: A parameter with the indicated address cannot be found in the message.
- kMostXML4CAPLParamTypeMismatch = -35: The function has attempted to read a value that does not have the compatible data type.
- kMostXML4CAPLEncodingMismatch = -36: The function cannot read the string or raw data, since the coding does not match.