Class: ScopeEdgeAnalysisResult
Valid for: CANoe DE • CANoe:lite DE This structure holds the minimal, maximal, standard deviation and average values which are measured by calling the function testWaitScopePerformEdgeAnalysis. The figure shows the measured values for a recessive to dominant change for the differential signal. NoteTo measure the delay and compensation time a secant is used. The secant points are by 10% and 90% of the voltage swing between the sample points of the recessive and dominant voltage. The secant is also used to measure the transition time (TT) and the slew rate (SR).
Methods
—Attributes
-
Keyword: ParameterUnit
- Description: The unit the parameter is measured
- Type: char[32]
- Access Limitations: Read-only
-
Keyword: ParameterUnit
- Description: The type of the parameter. Possible values are:
- 0 – TransitionTime (TT)
- 1 – Slew Rate (SR)
- 2 - Delay Time (TD)
- 3 – Half Value Time (TH)
- 4 – Compensation Time (TC)
- 5 – Response Time(TR)
- 6 – Settling Time (TS)
- Type: long
- Access Limitations: Read/Write
- Description: The type of the parameter. Possible values are:
-
Keyword: Min
- Description: Minimal value of the parameter
- Type: double
- Access Limitations: Read-only
-
Keyword: Max
- Description: Maximal value of the parameter
- Type: double
- Access Limitations: Read-only
-
Keyword: Avg
- Description: The average value of the parameter
- Type: double
- Access Limitations: Read-only
-
Keyword: StdDeviation
- Description: The standard deviation of the parameter
- Type: double
- Access Limitations: Read-only
-
Keyword: ScopeSamplePeriod
- Description: The sample period of the used scope device.
- Type: double
- Access Limitations: Read-only
-
Keyword: CountAnalyzedEdges
- Description: The count of measured edges
- Type: double
- Access Limitations: Read-only
-
Keyword: CountAnalyzedFrames
- Description: The count of measured frames
- Type: double
- Access Limitations: Read-only