Function Syntax
long testWaitScopePerformEdgeAnalysis(message frame, ScopeAnalyseRange analyseRange, dword flags, long thresholdStart long thresholdEnd, ScopeEdgeAnalyseResult parameter[], dword parameterCount, ScopeAnalyseHandle handle) //Form 1
long testWaitScopePerformEdgeAnalysis(linFrame frame, ScopeAnalyseRange analyseRange, dword flags, long thresholdStart long thresholdEnd, ScopeEdgeAnalyseResult parameter[], dword parameterCount, ScopeAnalyseHandle handle) //Form 2
long testWaitScopePerformEdgeAnalysis(frFrame frame, ScopeAnalyseRange analyseRange, dword flags, long thresholdStart long thresholdEnd, ScopeEdgeAnalyseResult parameter[], dword parameterCount, ScopeAnalyseHandle handle) //Form 3
long testWaitScopePerformEdgeAnalysis(char nodeName[], ScopeAnalyseRange analyseRange, dword flags, long thresholdStart long thresholdEnd, ScopeEdgeAnalyseResult parameter[], dword parameterCount, ScopeAnalyseHandle handle) //Form 4
Description
Perform an edge analysis for falling/rising edges of a specific frame or a complete node.
Parameters
- frame //Form 1,2,3: The CAN, LIN or FlexRay frame should be analyzed.
- nodeName //Form 4: The node should be analyzed.
- analyseRange: The start and end of the transition time measurement. See Class: scopeAnalyseRange.
- flags:
- Bits:
- 0: Define threshold level unit:
- 0 = Threshold level in mV
- 1 = Threshold level in %
- 1-3: Select signal for transition time measurement (only valid for CAN)
- Bit 1 = 1 Use CANhigh
- Bit 2 = 1 Use CANLow
- Bit 3 = 1 Use CANdiff
- 4-5: Rising/falling edge selection
- Bit 4 = 1 Use rising edges
- Bit 5 = 1 Use falling edges
- 6:
- 0 = Use last occurrence for transition time measurement, where the voltage level is above or below the threshold level.
- 1 = Use first occurrence for transition time measurement, where the voltage level is above or below the threshold level.
- All other bits are reserved and must be set to 0.
- thresholdStart, thresholdEnd: The start/end threshold should be used. Can be defined as % or mV value. These values are used to measure the transition time of an edge.
- parameters: The parameters should be measured. (See ScopeEdgeAnalyseResult)
- parameterCount: The parameter count which are contained within the parameters array.
- handle: A unique ID.
ScopeAnalyseHandle Selectors
- Keyword: handle
- Description: A unique ID
- Type: long
Return Values
- 1: Successful
- < 0: Error occurred. See EScopeCAPLFitDataReturnCode in ScopeBitAnalyse.cin