Skip to main contentReadByteArraySignalAsInteger
Valid for: CANoe DE • CANoe4SW DE
Function Syntax
dword ReadByteArraySignalAsInteger(signal aSignal, qword& value, dword direction, dword byteOrder, dword byteFillMode) // form 1
dword ReadByteArraySignalAsInteger(pdu aPDU, char signalName[], qword& value, dword byteOrder, dword byteFillMode) // form 2
Description
Reads the value of a byte array signal and treats it as a 64-bit integer. Use this function if you previously read the value of a byte array signal with the .raw64 selector. This selector works only for integer signals, but byte array signals were treated incorrectly as integer signals in CANoe versions < 12.0 SP3.
Parameters
- aSignal: A byte array signal
- aPDU: An AUTOSAR PDU with a byte array signal
- signalName: Name of the signal on the PDU
- value: The read value (out parameter)
- direction: Whether the rx signal (parameter value 0) or the tx signal value buffer (parameter value 1) shall be read.
- byteOrder: Byte order for interpreting the signal bytes.
- 0: little-endian (intel)
- 1: big-endian (motorola)
- byteFillMode: How the remaining bits of the 64-bit integer shall be filled if the signal has less than 64 bits. 0 means add 0 bits before the signal bits.
- 1: sign-extend. Add 0 or 1 bits before the signal bits, depending on the first signal bit.
- 2: Add 0 bits after the signal bits (effectively a right-shift of the value).
Return Values
- 0: No error
- 1: The signal has more than 64 bits.
- -2: The signal is not a byte array.
- 3: Signal not found on the PDU (form 2).
Example
If a signal has 56 bits (7 bytes) and the value shall be interpreted in motorola (big-endian) byte order, depending on the byteFillMode parameter, the following value will be read if the bytes of the signal are “91 23 45 67 89 AB CD”:
byteFillMode == 0: value == 0x009123456789ABCD // prepend 0s
byteFillMode == 1: value == 0xFF9123456789ABCD // sign-extension
byteFillMode == 2: value == 0x9123456789abcd00 // append 0s
If the value shall be interpreted in intel (little-endian) byte order, depending on the byteFillMode parameter, the following value will be read if the bytes of the signal are “EF CD AB 89 67 45 23”:
byteFillMode == 0: value == 0x0023456789ABCDEF // prepend 0s
byteFillMode == 1: value == 0x0023456789ABCDEF // sign-extension
byteFillMode == 2: value == 0x23456789ABCDEF00 // append 0s