Skip to main content

ILEnableTimingCyclic

Valid for: CANoe DE • CANoe4SW DE Note
  • This function is not available for all OEM add-ons — depends on the CANoeIL.
  • This function can be used in a global node outside the node context of the IL.

Function Syntax

long ILEnableTimingCyclic(char pduName[], int enable)

Description

Controls the cyclic timing of PDUs. The cyclic timing can be enabled/disabled. This function influences a simulation node with an assigned CANoe interaction layer.

Parameters

  • aPDUName: Name of the PDU that should be modified.
  • enable:
    • 0 = disable
    • 1 = enable

Return Values

  • 0: No error.
  • -1: General error.

Example