ILNodeResetPDUTimingCyclic

Valid for: CANoe DE • CANoe4SW DE Note
  • This function is only supported if the following components are used:
    • AUTOSAR PDU Interaction Layer (AsrPDUIL.dll) at the corresponding transmit node in the Simulation Setup.
    • AUTOSAR ≥ 4.2 database.
  • This function can be used in a global node outside the node context of the IL and in test modules.

Function Syntax

long ILNodeResetPDUTimingCyclic (dbMsg dbMessage, long TrueOrFalse)

Description

Resets the cyclic-timing to the values from the database. Possibly two timings (False and True) exist in parallel and are selected upon the current transmission mode of the PDU.

Parameters

  • dbMessage: The symbolic name of a PDU in the database.
  • TrueOrFalse:
    • 0: denotes the False timing
    • 1: denotes the True timing
    • 3: denotes the True and the False timing

Return Values

  • 0: No error
  • -10000: Unspecific error
  • -10001: Node or module not found
  • -10002: No suitable module available
  • -10003: Function is not supported by module
  • -10004: Module returns illegal value
  • other: Error in module