ethernetErrorPacket
Valid for: CANoe DE • CANoe4SW DEFunction Syntax
Description
Can be used in on ethernetErrorPacket handler to access packet data.Parameters
- packet var: Character string defining the object’s variable name.
Selectors
-
time_ns: Point in time, units: nanoseconds
Type:int64
Access Limitation: Read only -
dir
Type:byte
Access Limitation: Read only -
msgChannel: Application channel, i.e. Eth 1.
Type:word
Access Limitation: — -
hwChannel: Hardware channel. If not supported by network interface, value is 1.
Type:word
Access Limitation: Only with Vector Interfaces, i.e. VN5640, with operation mode with more than 1 hardware channel. Channel-based network access only -
hwPort: Port used for network-based access.
Type:ethernetPort
Access Limitation: network-based access only -
Length: Length of Ethernet payload data (starting after the Ethertype).
Type:word
Access Limitation: — -
FCS: Ethernet packet checksum. For some Ethernet hardware this value is not available (value 0).
Type:word
Access Limitation: Read only -
FrameLen: Frame duration in ns. For some Ethernet hardware this value is not available (value 0).
Type:word
Access Limitation: Read only -
SOF: Start-of-Frame time stamp in ns. For some Ethernet hardware this value is not available (value 0).
Type:word
Access Limitation: Read only -
Type: Ethertype
Type:word
Access Limitation: — -
Source: Source Ethernet MAC address. Only 6 bytes of the QWord are used and network byte order is used.
Type:qword
Access Limitation: — -
Destination: Destination Ethernet MAC address. Only 6 bytes of the QWord are used and network byte order is used.
Type:qword
Access Limitation: Read only -
ErrorCode: Channel-based mode in Rx direction (several error types can be set in one event):
- 1: Invalid length of the Ethernet packet
- 2: Invalid CRC of the Ethernet packet
- 4: Invalid data received
- 8: Collision detected (half duplex)
- 1: No link
- 2: Bypass enabled
- 3: Phy error
- 4: Overflow
- 5: Wrong time
- 6: Invalid CRC
- 7: Invalid length
- 8: No mirror
- 1: Invalid length of the Ethernet packet
- 2: Invalid CRC of the Ethernet packet
- 4: Invalid data received
- 8: Invalid src or dest MAC address
- 0x01: No link
- 0x02: PHY not yet configured
- 0x04: PHY bypass activated
- 0x08: RGMII converter in reset
- 0x10: Invalid length
- 0x20: Invalid CRC
- 0x40: Invalid src or dest MAC address
byte