Documentation Index
Fetch the complete documentation index at: https://notevil.mintlify.app/llms.txt
Use this file to discover all available pages before exploring further.
SomeIpCreateFieldConsumer
Valid for: CANoe DE • CANoe4SW DE
Function Syntax
dword SomeIpCreateFieldConsumer( dword csiHandle, long notificationId, long getterId, long setterId, char onFieldNotificationCallback[] );
Description
This function adds a Field Consumer to a Consumed Service Instance that was created by SomeIpCreateConsumedServiceInstance.
When a suitable field notification is received, the passed Notification Callback is called (see <OnSomeIpFieldNotification>).
A Field Consumer can be removed again using the SomeIpRemoveFieldConsumer function.
Parameters
- csiHandle: Handle of the Consumed Service Instance that was created with SomeIpCreateConsumerServiceInstance.
- notificationId: Identifier of the field notification. If the field does not support a notifier, the value -1 must be specified here.
- getterId: Identifier of the Field Getter method. In order to call a getter method, a method must be created with the
getterId beforehand (see also SomeIpCreateMethodCall and <OnSomeIpMethodResponse>). The method itself is then called with SomeIpCallMethod. If the field does not support a getter method, the value -1 must be specified here.
- setterId: Identifier of the Field Setter method. In order to call a setter method, a method must be created with the
setterId beforehand (see also SomeIpCreateMethodCall and <OnSomeIpMethodResponse>). The method itself is then called with SomeIpCallMethod. If the field does not support a setter method, the value -1 must be specified here.
- onFieldNotificationCallback: This callback function is called when the Field Notification message is received.
Return Values
- 0: An error occurred. The error can be evaluated using the SomeIpGetLastError function.
- >0: Handle of the created Field Consumer.
Example
In this example, it is assumed that the utilized field is contained in the FIBEX database that is assigned to the CANoe configuration. The field has the Notification ID 30, the Getter ID 31, and the Setter ID 32. The data type of the field is a standard data type (for example, UINT8).
variables
{
DWORD gMcGetter; // getter method call
DWORD gMcSetter; // setter method call
}
void Initialize()
{
CONST DWORD FieldNotificationID = 30;
CONST DWORD FieldGetterID = 31;
CONST DWORD FieldSetterID = 32;
DWORD aep; // Application Endpoint handle
DWORD csi; // consumed Service Instance handle
DWORD ceg; // consumed Eventgroup handle
// open Application Endpoint
aep = SomeIpOpenLocalApplicationEndpoint(17, 50002);
// create Service Instance
csi = SomeIpCreateConsumedServiceInstance(aep,12,1);
// create Eventgroup
ceg = SomeIpAddConsumedEventGroup(csi,300);
// create field consumer as well as getter and setter method calls
SomeIpCreateFieldConsumer(csi,FieldNotificationID,FieldGetterID,FieldSetterID,"OnFieldNotification");
gMcGetter = SomeIpCreateMethodCall(csi,FieldGetterID,"OnFieldGetterResponse");
gMcSetter = SomeIpCreateMethodCall(csi,FieldSetterID,"OnFieldSetterResponse");
}
void OnFieldNotification(DWORD pfHandle,DWORD messageHandle)
{
write ("Field Notification Received");
// do something here
}
void OnFieldGetterResponse(dword methodCallHandle, dword messageResponseHandle )
{
write ("Field Getter Response Received");
// do something here
}
void OnFieldSetterResponse(dword methodCallHandle, dword messageResponseHandle )
{
write ("Field Setter Response Received");
// do something here
}
on key 'g'
{
// call getter method
SomeIpCallMethod(gMcGetter);
}
on key 's'
{
// set value of field content (field has common data type so no value path is needed)
SomeIpSetValueDWord(gMcSetter,"",200);
// call setter method
SomeIpCallMethod(gMcSetter);
}