Open topic with navigation CAPL Functions » LIN » linSetGlobalInterByteSpace

linSetGlobalInterByteSpace

Valid for: CANoe DE

Function Syntax

dword linSetGlobalInterByteSpace(dword sixteenthBits);

Description

With this function, it is possible to change the inter-byte space for all frame responses. Inter-byte space is the period between the end of the stop bit of the preceding byte and the start bit of the following byte. By default, the inter-byte space is 0. Note: This function affects only frames published by the modeled LIN node(s), i.e., frames sent not by external hardware.

Parameters

  • sixteenthBits: Length of the inter-byte space to set [in units of 1/16th of bit time].
    • Value range: 0..65535. This corresponds to 0..4095.93 bit times.
    • For LIN standard compliance: The maximum space between the bytes cannot exceed 40% duration compared to nominal transmission time.

Return Values

On success, a value unequal to zero, otherwise zero.

Example

on key 's'
{
    if ( linSetGlobalInterByteSpace(16) != 0)
    {
        // from now on the inter-byte space in all frame responses is 1 bit time
        ...
    }
}
linSetInterByteSpacelinSetInterByteSpaceslinSetInterframeSpace