Function Syntax

  • long SecurityLocalStartControlSimulationNode(char nodeName[], char networkName[], dword orderNumber) // form 1
  • long SecurityLocalStartControlSimulationNode(char nodeId[], dword nodeIdType, char networkName[], dword orderNumber) // form 2

Description

Registers the calling node to a node in the Simulation Setup. Both nodes require the SecMgrCANoeClient Nodelayer. After a successful registration, the calling node can use all SecurityOfNode…() Functions to control the simulation node. The calling node receives all OnSecurityOfNode… callbacks from the specified node on the specified network. You have to call SecurityLocalStopControlSimulationNode to unregister. Form 2 allows to control non-database simulation nodes.

Parameters

  • char nodeName[]: The name of the node to control. This refers to the name declared in the database. (Form 1)
  • char nodeId[]: The name or title of the node to control. Use either the node name of a network node declared in the database or the node title declared in the Simulation Setup of the CANoe DE product and set parameter nodeIdType accordingly. (Form 2)
  • dword nodeIdType: Configure how the parameter nodeId shall be interpreted. Possible Values:
    • 1: nodeId refers to node name of a network node declared in the database
    • 2: nodeId refers to node title declared in the Simulation Setup of the CANoe DE product (If Network Node is set to <``<default>``>) (Form 2)
  • char networkName[]: The name of the network the node to control is on.
  • dword orderNumber: Defines the position in the ordered list, in which the callbacks are executed. Order number 1 is reserved for the simulation node itself. Order number 2 means that the callback is triggered directly after the simulation node (number 1), but before any other node who may have registered to a higher order number. Only one node can register to an order number. If the order number is already used, the registration fails.

Return Values

A Value of 1 means that the action was successful. A value less than or equal to 0 means error. A value larger than 1 means warning.
  • 1: Success
  • 0: Error, no details.
  • -1: Error - Specified Node unknown.
  • -2: Error - Specified Node unknown at the specified network.
  • -3: Error - StartControl failed.
  • -4: Error - Not registered at any node.
  • -5: Error - Not registered at specific node.
  • 2: Warning - Not registered at any node.
  • 3: Warning - Not registered at specific node.

Example

//form 1
on start
{
  dword result = 0;
  result = SecurityLocalStartControlSimulationNode("DatabaseNode", "CAN", 2);
  Write("SecurityLocalStartControlSimulationNode for network node with name DatabaseNode returned %i", result);
}

on stopMeasurement
{
  dword result = 0;
  result = SecurityLocalStopControlSimulationNode("DatabaseNode", "CAN");
  Write("SecurityLocalStopControlSimulationNode for network node with name DatabaseNode returned %i", result);
}

//form 2
on start
{
  dword result = 0;
  result = SecurityLocalStartControlSimulationNode("MyNode", 2, "CAN", 2); //Use the node title, if the node is not declared in the database (Network Node is set to <<default>>)
  Write("SecurityLocalStartControlSimulationNode for node with title MyNode returned %i", result);
}

on stopMeasurement
{
  dword result = 0;
  result = SecurityLocalStopControlSimulationNode("MyNode", 2, "CAN"); //Use the node title, if the node is not declared in the database (Network Node is set to <<default>>)