Skip to main contentTestJoinFrFrameErrorEvent
Valid for: CANoe DE • CANoe4SW DE
Function Syntax
long TestJoinFrFrameErrorEvent (dbFrFrame aFrame)
long TestJoinFrFrameErrorEvent (dword aSlotId, dword aBaseCycle, dword aCycleRepetition, dword aChannelMask)
Description
Completes the current set of “joined events” with the transmitted event. This function does not wait.
Note:
Dependent on the used parameter type the appropriate bus context in a multibus environment has only to be set before the function is called if the corresponding database object will be ambiguous. Further information on site MultiBus Environment.
Parameters
- aFrame: Symbolic frame as it is defined in the database.
- aSlotId: Numeric slot identifier. Value range: 1…2047
- aBaseCycle: Numeric base cycle. This value must be less than the repetition factor. Together with the repetition factor this value determines the “Cycle Multiplexing”. Value range: 0…63
- aCycleRepetition: Cycle repetition factor. Together with the base cycle this value determines the “Cycle Multiplexing”. Value has to be a power to 2 (1, 2, 4, 8, 16, 32 or 64).
- aChannelMask: Channel of the transmission message. Values:
- 1: Channel A
- 2: Channel B
- 3: Channel A+B
Return Values
- -3: Join error
- -1: General error, for example, functionality is not available
- > 0: Number of the joined event
Example
For an example see function TestWaitForFrFrame and replace all FrFrame by FrFrameError.
TestWaitForFrFrameError • TestGetWaitFrFrameErrorData • TestWaitForAnyJoinedEvent • TestWaitForAllJoinedEvents