TestJoinFrStartCycleEvent
Valid for: CANoe DE • CANoe4SW DEFunction Syntax
long TestJoinFrStartCycleEvent (dword aCycle)long TestJoinFrStartCycleEvent (dword aBaseCycle, dword aCycleRepetition)
Description
Completes the current set of “joined events” with the transmitted event. This function does not wait. Note: Consider to set always the appropriate bus context in a multibus environment before the function is called. Further information on site MultiBus Environment.Parameters
-
aCycle: Numeric cycle identifier.
Value range: 0…63 -
aBaseCycle: Numeric base cycle. This value must be less than the repetition factor. Together with the repetition factor this value determines the “Cycle Multiplexing”.
Value range: 0…63 -
aCycleRepetition: Cycle repetition factor. Together with the base cycle this value determines the “Cycle Multiplexing”.
Value has to be a power to 2 (1, 2, 4, 8, 16, 32 or 64).
Return Values
- -3: Join error
- -1: General error, for example, functionality is not available
- > 0: Number of the joined event