Function Syntax

  • long TestJoinFrStartCycleEvent (dword aCycle)
  • long TestJoinFrStartCycleEvent (dword aBaseCycle, dword aCycleRepetition)

Description

Completes the current set of “joined events” with the transmitted event. This function does not wait. Note: Consider to set always the appropriate bus context in a multibus environment before the function is called. Further information on site MultiBus Environment.

Parameters

  • aCycle: Numeric cycle identifier.
    Value range: 0…63
  • aBaseCycle: Numeric base cycle. This value must be less than the repetition factor. Together with the repetition factor this value determines the “Cycle Multiplexing”.
    Value range: 0…63
  • aCycleRepetition: Cycle repetition factor. Together with the base cycle this value determines the “Cycle Multiplexing”.
    Value has to be a power to 2 (1, 2, 4, 8, 16, 32 or 64).

Return Values

  • -3: Join error
  • -1: General error, for example, functionality is not available
  • > 0: Number of the joined event

Example

For an example see function TestWaitForFrStartCycle. TestWaitForFrStartCycleTestGetWaitFrStartCycleDataTestWaitForAnyJoinedEventTestWaitForAllJoinedEvents