Skip to main contentTestWaitForFrNullFrame
Valid for: CANoe DE • CANoe4SW DE
Function Syntax
long TestWaitForFrNullFrame (dbFrFrame aFrame, dword aTimeout);
long TestWaitForFrNullFrame (dword aSlotId, dword aBaseCycle, dword aCycleRepetition, dword aChannelMask, dword aTimeout);
long TestWaitForFrNullFrame (dword aTimeout);
Description
Waits for the occurrence of the specified FlexRay Null Frame. Should the event not occur before the expiration of the time aTimeout, the wait condition is resolved nevertheless.
When no Null Frame is specified the wait condition is resolved on any FlexRay Null Frame.
Note: Dependent on the used parameter type the appropriate bus context in a multibus environment has only to be set before the function is called if the corresponding database object will be ambiguous. Further information on site MultiBus Environment.
Parameters
- aFrame: Frame to be awaited as it is defined in the database.
- aSlotId: Numeric slot identifier. Value range: 1…2047
- aBaseCycle: Numeric base cycle. This value must be less than the repetition factor. Together with the repetition factor this value determines the “Cycle Multiplexing”. Value range: 0…63
- aCycleRepetition: Cycle repetition factor. Together with the base cycle this value determines the “Cycle Multiplexing”. Value has to be a power to 2 (1, 2, 4, 8, 16, 32 or 64).
- aChannelMask: Channel of the transmission message. Values:
- 1: Channel A
- 2: Channel B
- 3: Channel A+B
- aTimeout: Maximum time that should be waited [ms] (Transmission of 0: no timeout controlling)
Return Values
- -2: Resume due to constraint violation
- -1: General error, for example, functionality is not available
- 0: Resume due to timeout
- 1: Resume due to event occurred
Example
For an example see function TestWaitForFrFrame and replace all FrFrame by FrNullFrame.