SCC_CreatePowerDeliveryResAC_ISO
Valid for: CANoe DE • CANoe4SW DEFunction Syntax
Description
Creates a Power Delivery Response message for sending, using the AC syntax.Parameters
- SessionID: 8-byte long SessionID of SCC connection, range: 0 - 0xFF FF FF FF FF FF FF FF.
- ResponseCode: Acknowledgment status of the message. The list of possible response codes you find on page SCC_SetResponseCode.
- NotificationMaxDelay: Time until the vehicle is expected to react on the notification (for AC_EVSEStatus).
- StatusFlags: Flags for AC_EVSEStatus:
- StatusFlags[0] = PowerSwitchClosed
- StatusFlags[1] = RCD
- Notification: Notification about an action that the charge point wants the vehicle to perform (for AC_EVSEStatus).
Return Values
- 1: If successful.
- 0: Else (message cannot be sent).