Skip to main content

TestEnableUpdateBit

Valid for: CANoe DE • CANoe4SW DE Note
This function is not available for all OEM add-ons - depends on the CANoeIL.

Function Syntax

long TestEnableUpdateBit (dbSignal aSignal);

Description

Re-enables the standard behavior of the update bit, after it has been disabled with TestDisableUpdateBit. This function influences a simulation node with an assigned CANoe Interaction Layer. Note
Dependent on the used parameter type the appropriate bus context in a multibus environment has only to be set before the function is called if the corresponding database object will be ambiguous. Further information on site MultiBus Environment.

Parameters

  • aSignal: Signal that should be reset to update bit standard behavior.

Return Values

  • 0: No error.
  • -1: General error.

Example

// disables the update bit of signal ‘DoorStatus_UB’ for 1000 ms
TestDisableUpdateBit(DoorStatus_UB, 0);
TestWaitForTimeout(1000);
TestEnableUpdateBit(DoorStatus_UB);