Skip to main contentTestGetWaitPDUData
Valid for: CANoe DE • CANoe4SW DE
Function Syntax
long TestGetWaitPDUData (PDU * aPDU); // form 1
long TestGetWaitPDUData (dword explicitJoinIndex, PDU * aPDU); // form 2
Description
If a valid PDU is the last event that triggers a wait instruction, the PDU’s content can be called up with form 1.
Form 2 can only be used for joined events. The number of the joined event (return value of TestJoin...) is here being used as an index.
Parameters
- aPDU: PDU variable of type PDU that should be filled in with this function. It has to be either a type free PDU variable, or a PDU variable that was created for the PDU type that triggered the wait instruction.
- explicitJoinIndex: Number of the joined event corresponds with the return value of
TestJoin....
Return Values
- 0: Data access successful.
- -1: Data access could not be executed, the last event was not a PDU event.
- -2: Data access could not be executed; the explicitJoinIndex is out-of-range.
- -7: Parameter aPDU is a typed PDU variable, but the returned PDU has a different type.
Example
—
TestJoinPDUEvent • TestWaitForPDU