Function Syntax

  • long TestGetWaitPDUData (PDU * aPDU); // form 1
  • long TestGetWaitPDUData (dword explicitJoinIndex, PDU * aPDU); // form 2

Description

If a valid PDU is the last event that triggers a wait instruction, the PDU’s content can be called up with form 1. Form 2 can only be used for joined events. The number of the joined event (return value of TestJoin...) is here being used as an index.

Parameters

  • aPDU: PDU variable of type PDU that should be filled in with this function. It has to be either a type free PDU variable, or a PDU variable that was created for the PDU type that triggered the wait instruction.
  • explicitJoinIndex: Number of the joined event corresponds with the return value of TestJoin....

Return Values

  • 0: Data access successful.
  • -1: Data access could not be executed, the last event was not a PDU event.
  • -2: Data access could not be executed; the explicitJoinIndex is out-of-range.
  • -7: Parameter aPDU is a typed PDU variable, but the returned PDU has a different type.

Example

TestJoinPDUEventTestWaitForPDU