Skip to main content

TestGetWaitFrSymbolData

Valid for: CANoe DE • CANoe4SW DE

Function Syntax

long TestGetWaitFrSymbolData (FrSymbol aSymbol);
long TestGetWaitFrSymbolData (dword index, FrSymbol aSymbol);

Description

If a FlexRay symbol event is the last event that triggers a wait instruction, the event’s content can be called up with the first function. The second function can only be used for “joined events”. The number of the “joined event” (return value of “testJoin…”) is here being used as an index.

Parameters

  • aSymbol: Event structure that should be filled in with this function (for selectors see event procedure on FRSymbol).
  • Index: Number of the “joined event” corresponds with the return value of “testJoin…”.

Return Values

  • 0: Data access successful
  • -1: Data access could not be executed, the last event was not a FlexRay POC event

Example

For an example see function TestWaitForFrSymbol. TestWaitForFrPOCStateTestJoinFrSymbolEvent