Return Values

CAPL Functions » Diagnostics » Error Codes Valid for: CANoe DE The following values can be returned:
  • 0: No error, success.
  • >0: Number, e.g. length of the given text.
  • -100: The input provided on function call is not consistent or sufficient. Check the arguments provided to the function call.
  • -99: The object’s response is pending, therefore cannot delete it. Delay the operation until the object is no longer accessed.
  • -98: The handle is not assigned to a diagnostic object. Check that the initialization of the object worked, i.e. diagSetTarget was successful.
  • -97: The parameter does not exist in this object, or is constant. Make sure that the parameter exists in the diagnostic object.
  • -96: Function not implemented yet.
  • -95: Accessing CANdelaLib lead to error ’…’ for ’…’ Parameter or object ’…’ not defined! Make sure the parameter is defined in the accessed diagnostic object.
  • -94: Diagnostics was not initialized for the node, i.e. no SetEcu/Target called. Make sure diagSetTarget is called and sets an existing target successfully.
  • -93: The specified callback was not found. Please refer to Diagnostics: Connection of the Communication Layer for details.
  • -92: There was an error on TP level. Check the Write window for further information.
  • -91: Only one request/response can be sent at a time! Make sure that the processing of the previous object is finished.
  • -90: Test function outside TestCase, or Tester-only function called in ECU, or vice-versa. Requests can only be sent from nodes configured as tester.
  • -89: No Seed & Key library was specified. Configure a Seed & Key DLL.
  • -88: The Seed & Key library did not contain a matching Seed & Key function. Configure a Seed & Key DLL that holds the expected Seed & Key function.
  • -87: The Seed & Key library couldn’t be loaded. Ensure that the correct Seed & Key path and filename is configured.
  • -86: The buffer was too small. Increase the buffer size.
  • -85: The seed array size is too large. Decrease the seed array size.
  • -84: The security level is invalid. Use a correct security level.
  • -83: The variant is invalid. Use a supported variant.
  • -82: An unspecified error occurred.
  • -81: The function cannot perform the action because of wrong HW. Ensure correct HW devices.
  • -80: No matching request was found to perform the action.
  • -79: No diagnostic channel found.
  • -78: No suitable class or request was found. Ensure that the qualifiers are defined in the diagnostic description.
  • -77: A timeout happened. The ECU did not send a response for the request.
  • -76: Transmission failed. The request or response could not be sent.
  • -75: The class was not found in the diagnostic description. Ensure that the class qualifiers is defined in the diagnostic description.
  • -74: Creation of the PDU bytes for a diagnostic object failed! Make sure that all parameters in the object are set to valid values.
  • -73: During processing a negative response was received. Ensure that the ECU responds correctly.
  • -72: No key could be calculated. Ensure that the correct Seed & Key DLL is configured.
  • -71: The key was not accepted. Ensure that the correct Seed & Key DLL is configured.
  • -70: The diagnostic object is too small. Check the index used.
  • -199: The authentication tool is not properly configured.
  • -198: Authentication was rejected. Ensure that there is no other task running in parallel.
  • -197: This mode is not implemented.
  • -196: Invalid handle.
  • -195: Error in security add-on. Check the backend tool logs for potential problems.
  • -194: Security not usable. Check whether a Security Profile supporting diagnostics is assigned.
  • -193: Missing data.
  • -192: Signal length mismatch.
  • -191: General error.
  • -190: Unknown file type.
  • -189: File could not be read (e.g., due to missing permissions).
  • -188: File could not be parsed.
  • -187: At least one domain in variant coding could not be set.
  • -186: Unknown/unsupported generic task parameter.
  • -185: Invalid ECU response. Check the Trace window and verify that the ECU communication is as expected.
  • -184: Channel not ready.
  • -183: Invalid value.
  • -182: Invalid serialized data.
  • -181: The client version is not supported.
  • -180: Timeout.
  • -179: The task was aborted, as no measurement is running.
  • -178: The specified job qualifier does not exist in the CDD file. Verify that a security job with the expected qualifier exists in the CDD file.
  • -177: Interpretation error.
  • -176: Communication error.
  • -175: Unexpected response.
Note: For the following return values please check the security add-on and the configuration of the Security Manager.