diagSetTarget
Valid for: CANoe DEFunction Syntax
Description
Sets the target ECU with which the tester shall communicate from now on and configures/establishes the communication channel to that ECU. Note- This function cannot be used in the on prestart handler, is only to be used inside a CAPL tester node and must not be called from inside a CAPL ECU node which simulates diagnostics.
- In case you are implementing a diagnostic ECU simulator node, assign the diagnostic description to the node by selecting the ECU’s name in the Function/Node combo box of the Diagnostics configuration dialog / Assignments tab.
- Instead of assigning a simulation node in the configuration dialog, you may alternatively use the function DiagInitECUSimulation to establish a link between your CAPL code and the corresponding diagnostic description.
- From now on the tester will interpret and use all diagnostic objects in the CAPL code of this node as defined in the respective diagnostic description file.
- From now on the tester will use the SeedKey DLL defined for this target in the diagnostic configuration dialog when computing a security key with diagGenerateKeyFromSeed().
- All diagnostic objects (requests/responses) defined in the CAPL code are re-initialized for the given target. If DiagSetTarget() was called for the same or a different target before, the request/response objects will no longer keep modifications made in a previous session with a previous target ECU.
- DiagSetTarget shall not be called in the “on preStart” handler of a test module, since it would be called only once when the measurement starts. It is recommended to call it in the “preparation” phase of an XML test module, or to make sure programmatically that it is called before any test case using diagnostics is executed.
- The communication layer is configured:
- In case of a CAPL Callback interface (CCI) being used, the function _Diag_SetChannelParameters is called to configure the parameters of the underlying TP modeling library.
- If no CCI is implemented, a built-in diagnostic channel is configured according to the network type to which the diagnostic description is attached and according to the communication parameters of the selected diagnostic interface. For connection oriented transport protocols (like e.g. VW TP 2.0) furthermore not only the parameters of the connection are configured, but a communication channel is actually established between tester and ECU.
Parameters
- ecuName: Qualifier of the ECU as set in the diagnostic configuration dialog for the respective diagnostic description (CDD/ODX).