diag_SetDataSegmentation

Valid for: CANoe DE Note
This function is only available with the implementation of the generic CAPL callback interface!

Function Syntax

long diag_SetDataSegmentation
(long mode, DWORD maxSegmentSize, DWORD segmentSeparationTime);

Description

Configures the segmentation of diagnostic data at the transmission.

Parameters

  • mode
    Segmentation mode defines whether the transferred data must be segmented (used with VW TP 2.0).
    • Values:
      • 0: default value, no segmentation; other function parameters are ignored; no segment header is used (ISO TP)
      • 1: Segment header (2 byte length value) is used; segmentation is activated, if the maxSegmentSize > 0 (VW TP 2.0)
  • maxSegmentSize
    Maximum length of a segment, header inclusive.
    The value 0 implies that the segment may have any length.
  • segmentSeparationTime
    Distance between sending of the segments in milliseconds.

Return Values

Error code

Example