diagGetLastCommunicationError
Valid for: CANoe DEFunction Syntax
Description
Returns the error code of the last diagnostic request.Parameters
—Return Values
- -1: There was no request yet or no error occurred.
- 0: The response wasn’t received in expected time.
- 1: Time for transmission of the CAN frame on the receiver side expired.
- 2: Time for transmission of the CAN frame on the sender side expired.
- 3: Time until reception of the next Flow Control expired.
- 4: Time until reception of the next Consecutive Frame expired.
- 5: Not specified communication error.
- 6: The response wasn’t received in the expected extended time.
- 7: A previously queued request was canceled.
- 8: Not possible to forward the message to the Bus System Proxy (not defined/open or driver error).
- 9: The response wasn’t received in the expected RC21 completion time.
FlexRay Specific ComErrors
- 100: The request to send some data was rejected since another transmission is in progress.
- 101: A reception was active when FF or SF was received.
- 102: A negative ACK was received for acknowledged connections.
- 103: The bus did not confirm transmission of a frame in time.
- 104: The transmitter did not receive a FC (or AF) in time.
- 105: The receiver did not receive the next CF in time.
- 106: The peer rejected the data since it is too long.
- 107: Peer sent an undefined ACK.
- 108: A message received is not fit for processing, e.g. a First Frame where a Single Frame would have sufficed.
- 109: Receiver has sent too many wait frames and must therefore abort the transfer!
- 110: Receiver has requested the resending of an illegal frame, e.g. the First Frame.
- 111: ISO: Receiver requested the transfer to be aborted.
K-Line Specific ComErrors
- 200: StartCommunication request wasn’t answered by the ECU.
General Error Codes
- 600: The requested function isn’t supported.