ChkStart_LINSyncBreakTimingViolation
Valid for: CANoe DE • CANoe4SW DEFunction Syntax
Constructor
ConstructorDescription
Checks the timing of the synchronization break field in LIN headers. An event will be generated if the measured length [in bit times] of break low phase is outside of the specified range. Note: Dependent on the used parameter type, the appropriate bus context in a multibus environment has only to be set before the function is called if the corresponding database object will be ambiguous. Further information on site MultiBus Environment.Parameters
-
MinBreakLen
0: Minimum length of break low phase shall not be checked\>0: Minimum allowed length of break low phase- Unit: bit time
-
MaxBreakLen
0: Maximum length of break low phase shall not be checked\>0: Maximum allowed length of break low phase- Unit: bit time
-
CaplCallback
- Name of CAPL callback function to be called on generated event. In simulation nodes, this parameter has to be set. In test modules, this parameter is optional.
Return Values
0: Check could not be created and must not be referenced\> 0: Check was created successfully and may be referenced using the returned (handle-) value.
Possible Errors
- Range specified for synch break length is invalid
- CAPL callback does not exist