Iso11783IL_TIMOperatorAcknowledgeStartOfMotion

Valid for: CANoe DE • CANoe4SW DE

Function Syntax

long Iso11783IL_TIMOperatorAcknowledgeStartOfMotion( ); // form 1
long Iso11783IL_TIMOperatorAcknowledgeStartOfMotion(dbNode server); // form 2

Description

Performs an operator acknowledgment to start motion. If the server supports facility Start vehicle motion and property requireAcknowledgeOfStartOfMotion is set to 1 (Iso11783IL_TIMSetProperty) then the function Iso11783IL_TIMOperatorAcknowledgeStartOfMotion must be called before the client can start its movement. An operator acknowledgment to start motion has to be performed once after the TIM server is activated.

Parameters

  • node: Simulation node to apply the function.

Return Values

  • 0: Function has been executed successfully
  • Other: An error has occurred, see error codes

Example