Iso11783IL_TIMSetComplianceCertification
Valid for: CANoe DE • CANoe4SW DEFunction Syntax
Description
Sets the content of message ISOBUS Compliance Certification (see ISO11783-7 B.27). If the ISOBUS Compliance Certification message is in the Tx list of the TIM node and a Request for PGN 64834 (FD42h) is received then the ISOBUS Compliance Certification message is sent using the specified parameter (ISOBUS Compliance Certification message revision is always 1).Parameters
-
testProtocolPublicationYear: The publication year of the compliance test protocol to which the certification test was performed.
Range: 2000..2061. -
testProtocolRevision: Revision of the compliance test performed.
Range: 0..31. -
laboratoryType: Type of certification laboratory.
- 0: Non-certified laboratory/self-certification
- 1: AEF certified laboratory
- 2: Reserved
- 3: Not available (not certified)
-
laboratoryID: Manufacturer code of the laboratory that performed the compliance test.
Range: 0..2047. -
referenceNumber: Certification reference number assigned by a certification laboratory.
Range: 0..65355. - participant: TIM participant (TIM server or TIM client).
Return Values
- 0: Property has been set successfully
- < 0: An error has occurred, see error codes