CAPL Functions » ISO11783 » Task Controller Interaction Layer (TC IL) » TCIL_DelayRxMessage
TCIL_DelayRxMessage
Valid for: CANoe DE • CANoe4SW DE
Function Syntax
long TCIL_DelayRxMessage(dword pgn, dword sourceAddress, qword filterMask, qword filterValue, dword delay); // form 1
long TCIL_DelayRxMessage(dword pgn, dword sourceAddress, qword filterMask, qword filterValue, dword delay, char sysVarNameWithPath[]); // form 2
long TCIL_DelayRxMessage(dbNode node, dword pgn, dword sourceAddress, qword filterMask, qword filterValue, dword delay); // form 3
long TCIL_DelayRxMessage(dbNode node, dword pgn, dword sourceAddress, qword filterMask, qword filterValue, dword delay, char sysVarNameWithPath[]); // form 4
Description
A message described in the function is only forwarded to the simulation node after the defined delay. As a result, the simulated node reacts to the message only after this delay.
You can also define a system variable which is set if the specified message is received.
To revert this command you can use TCIL_ResetDelayedRxMessage or TCIL_ResetAllDelayedRxMessage.
Parameters
- pgn: Parameter Group Number (with data page) of the message to be delayed.
- sourceAddress: Source address of the message to be delayed (or 0xFFFFFFFF if the source address is to be ignored).
- filterMask: Defines the bits of the first 8 Bytes of the message payload which shall be used to identify (filter) the message. Use value 0 if you don’t want to filter by message payload.
- filterValue: Defines the value of the bits of the first 8 bytes of the message payload which shall be used to identify (filter) the message. If the value of the bits of a received message identified by filterMask is equal to this value, this message is delayed.
- sysVarNameWithPath: Name of a system variable (all namespaces inclusive) which is set to 1 if the specified message is received. You can specify an empty string if no system variable shall be used.
- delay: Delay in [ms]. After this delay the message is forwarded to the simulated node. If delay is 0 then the message is forwarded without any delay (e.g. if you only want to wait for the message using the specified system variable and the function testWaitForSysVar).
- node: Simulation node to apply the function.
Return Values
- 0: Function has been executed successfully
- -102: An invalid parameter is used
Example
—