Iso11783PDDSetLogTrigger
Valid for: CANoe DE • CANoe4SW DEFunction Syntax
Description
A measurement command can be executed with this function. It can be used in the callback function Iso11783PDDOnDefaultLogRequest to activate the default logging.Parameters
- ecuHandle: Handle of the ECU, must previously have been created with Iso11783CreateECU.
- command: Measurement command:
- 4: Time Interval
- 5: Distance Interval
- 6: Minimum within Threshold
- 7: Maximum within Threshold
- 8: Change Threshold
- ddi: Data Dictionary Identifier, 0x0000..0xFFFF
- elNum: Element number, 0x000..0xFFF
- value: Depends on
command- Time Interval: time in ms
- Distance Interval: distance in mm
- Minimum within Threshold / Maximum within Threshold / Change Threshold: value of the process variable