Iso11783PDDSetLogTrigger

Valid for: CANoe DE • CANoe4SW DE

Function Syntax

long Iso11783PDDSetLogTrigger( dword ecuHandle, dword command, ulong ddi, ulong elNum, ulong value );

Description

A measurement command can be executed with this function. It can be used in the callback function Iso11783PDDOnDefaultLogRequest to activate the default logging.

Parameters

  • ecuHandle: Handle of the ECU, must previously have been created with Iso11783CreateECU.
  • command: Measurement command:
    • 4: Time Interval
    • 5: Distance Interval
    • 6: Minimum within Threshold
    • 7: Maximum within Threshold
    • 8: Change Threshold
  • ddi: Data Dictionary Identifier, 0x0000..0xFFFF
  • elNum: Element number, 0x000..0xFFF
  • value: Depends on command
    • Time Interval: time in ms
    • Distance Interval: distance in mm
    • Minimum within Threshold / Maximum within Threshold / Change Threshold: value of the process variable
Use value 0 to disable a trigger.

Return Values

error code

Example

void Iso11783PDDOnDefaultLogRequest(dword ecuHandle) {
    Iso11783PDDSetLogTrigger(ecuHandle, 4, 0x0100, 0, 1000);
    Iso11783PDDSetLogTrigger(ecuHandle, 4, 0x0101, 0, 1000);
}