Skip to main content

Iso11783OPChangeEndPoint

Valid for: CANoe DE • CANoe4SW DE

Function Syntax

long Iso11783OPChangeEndPoint( dword ecuHandle, dword objectID, dword width, dword height, dword direction );

Description

The function changes the length and alignment of a line object. A Change End Point command is sent to the Virtual Terminal.

Parameters

  • ecuHandle: Handle of the ECU (must be created with Iso11783CreateECU)
  • objectID: Object ID of the line object
  • width: Width of the bounding rectangle of the object
  • height: Height of the bounding rectangle of the object
  • direction: Alignment of the line
    • 0: from top/left to bottom/right
    • 1: from bottom/left to top/right

Return Values

0 or error code

Example

Iso11783OPChangeEndPoint( handle, 1200, 50, 20, 0 );