Skip to main content

Iso11783OPSetLabel

Valid for: CANoe DE • CANoe4SW DE

Function Syntax

long Iso11783OPSetLabel( dword ecuHandle, dword objectID, 
 dword stringVarIdD, dword fontType, dword graphID );

Description

A Set Label command is sent to the Virtual Terminal.

Parameters

  • ecuHandle: Handle of the ECU (must be created with Iso11783CreateECU)
  • objectID: Object ID which is assigned to the label
  • stringVarID: Object ID of the string variable object
  • fontType: Font type
  • graphID: Object ID of a graphical object

Return Values

0 or error code

Example

Iso11783OPSetLabel( handle, 1200, 1250, 1, 1260 );