Skip to main content

CANopenLssActivateBitTimingParameters

Valid for: CANoe DE • CANoe:lite DE • CANoe4SW DE

Function Syntax

dword CANopenLssActivateBitTimingParameters(dword switchDelay);

Description

The LSS master activates the bit timing of a LSS slave. The bit timing can be configured using the function CANopenLssConfigureBitTimingParameters.

Parameters

  • switchDelay: Delay in ms until the bit timing is active.

Return Values

  • 0: Successful
  • 1: Invalid channel (not CAN or inactive)

Example

// Activate bit timing with 500ms delay
CANopenLssActivateBitTimingParameters(500);