Function Syntax

dword CANopenLssSwitchModeSel (dword vendorId, dword productCode, dword revisionNo, dword serialNo);

Description

Sets LSS slaves to the configuration mode or leave the mode.

Parameters

  • vendorId: Vendor Id of the device.
  • productCode: Product code of the device.
  • revisionNo: Revision number of the device.
  • serialNo: Serial number of the device.

Return Values

  • 0: Successful
  • 1: Invalid channel (not CAN or inactive)

Example

// Switch a device with vendor-ID 5, product code 0, revision number 1 and serial number 123 to configuration mode
CANopenLssSwitchModeSel(5, 0, 1, 123);