coTfsSetFailControl

Valid for: CANoe DE • CANoe:lite DE • CANoe4SW DE

Function Syntax

long coTfsSetFailControl( dword controlValue );

Description

Determines the behavior of CANopen test feature set tests. The entries in the test report can be switched with this function, that is, a test that in the default setting 0 has passed also receives the note “passed” in the test protocol. Conversely, a failed test receives the note “failed”. The call of this function with the parameter 1 reverses the behavior. If the device should pass a test, failed is in the test report and vice-versa. This behavior can be used to create a negative test. After measurement start, the setting 0 is always active. The return value of the test functions themselves in the CAPL program is never changed, only the protocol is adjusted.

Parameters

  • controlValue
    • 0: normal behavior (default)
    • 1: inverted behavior
    • 2: the test case is not marked with pass or fail in the test report, the user must ensure the corresponding entries himself

Return Values

Error code

Example

coTfsSetFailControl (1); // invert report behavior

// run some negative tests

coTfsSetFailControl (0); // switch back to normal behavior